Page 30 - North American Clean Energy May/June 2019 Issue
P. 30

solar energy
Full range non-indicating time delay fuse
Mersen’s Non-Indicating Class J Time Delay Fuse series o ers a full range of ampere ratings between 8-600A in both indicating and non- indicating categories. Mersen’s new Non-Indicating Class J Time Delay fuse series satis es the National Electrical Code requirements for use in Class I Division 2 hazardous locations. Another key bene t of the Mersen Non-Indicating Class J Time Delay Fuse series is that they possess the same size, mounting terminals, and ratings as the Mersen SmartSpot Class J Fuses.  e UL/CSA Listed Mersen Non-Indicating Class J Time Delay Fuse series is readily identi able by su xing the letter “N” to the Catalog Number of the equivalent Mersen SmartSpot Class J Time Delay Fuse and is available immediately.
Mersen /// ep.mersen.com
Rugged AC  lter capacitors
TDK Corporation’s EPCOS B32754* to B32758* series of AC  lter capacitors cover a range of voltages from 250VAC to 400VAC and o er capacitances of between 1 μF and 70 μF.  e capacitors comply with IEC 61071: 2007 and are robust, even at high humidity.  is has been veri ed in a temperature, humidity, bias (THB) test at 60°C, 95% relative humidity and an applied rated voltage for 1344 hours, corresponding to 56 days, in according to IEC 60384 14:2013/AMD1:2016 Grade 3 Test A.  e capacitors are designed for a maximum operating temperature of 105°C, and their epoxy resin- lled case conforms to UL 94 V-0. Depending on capacitance and rated voltage, the lead spacing is 27.7mm, 37.5mm, or 52.5mm.  e capacitors are suitable for demanding applications in industrial electronics.  ese include, for example, output  ltering for power supplies, frequency converters for drives, and renewable energy, or UPS systems.
TDK Corporation /// www.tdk-electronics.tdk.com
Hazardous location C1D2 solar panel with batteries Larson Electronics has released a new hazardous location solar powered panel system with batteries that is rated for use in Class I Division 2 hazardous locations, where o -grid power is required or desired for continuing operations in remote or temporary environments.
 is solar powered control system features four, 190W solar panels and four 12V 250aH 8D batteries.  e HAL-SPSM-.75KW-12V-1000AH from Larson Electronics is a solar panel unit designed speci cally for Class I Division 2 hazardous.  is four solar panel unit includes four 12V 250aH 8D batteries, which provide reliable power for connected equipment. Runtime for this system is 72 hours maximum (no sun is present) when powering one 190W 12V electrical device. A heavy-duty powder coated, corrosion resistant aluminum enclosure protects the valve regulated lead acid batteries and controls, and features pad-lockable hasps for defense against tampering.  is unit is also included with circuit breakers o ering short circuit protection.  e solar panels are mounted via a skid mount fame for  at surfaces, and the battery enclosure can be mounted on poles or on the  oor with rear-access U-bolts.
Larson Electronics LLC
/// www.larsonelectronics.com
1500 Volt 30 Amp I-V Curves Solmetric PV Analyzer
Highest accuracy and throughput
Largest display with best array troubleshooong features
Database of 50,000 PV modules Measures up to 1500V at 30A 3000 wireless sensor range
Expert tools Beeer solar
www.solmetric.com
30
MAY•JUNE2019 /// www.nacleanenergy.com
New!


































































































   28   29   30   31   32