Page 40 - North American Clean Energy March April 2018 Issue
P. 40
solar spotlight: tracking systems
SEE AD ON PAGE 28
SEE AD ON PAGE 38
Solar FlexRack
Type of Tracker: TDP 2.0 Tracker
with BalanceTrac (Single-axis)
Drive System: Zero-Maintenance Distributed Slew Drive
Tracker Height: Project specific Tracker Length: 304' (90 module
row)
Pile Count: 7 modules per pile
Modules per Row: Up to 90 modules
Module Mount: Self-aligning, auto spacing direct bolt
Slope Tolerance: Up to 10° n/s Tracking Range: Up to 110° (+/- 55°)
Standard Configuration: 1 in Portrait, 2 in Landscape (crystalline); 4 in Landscape (thin film)
Preventative Maintenance Required: None
Tracker Power Consumption: 31kWh per tracker/year or self-powered
Certifications: UL 2703 (2018) Key Features:
• Adaptable with crystalline or thin film, optimized for 1000V and 1500V modules and installation is easy with no prying, adjusting, or special tools;
• Self powered option now available, and independently driven rows provide easy access for mowing, cleaning, and other maintenance;
• Lower per-unit fixed costs for BOS savings; • Programmable technology to mitigate
inclement climatic conditions;
• Independent tables increase design flexibility to maximize land use;
• Smart backtracking reduces row shading to optimize energy production for high power density.
www.solarflexrack.com
STI Norland
Type of Tracker: Horizontal, single-axis,
multi-row
Drive System: Worm Gear - Arm/Drive
Tracker Length: 200' (61m)
Tracker Height: 5' (1.5m)
Pile Count: 10 piles per row
Modules per Row: 62
Module Mount: Bolt, clamp, rivet
Slope Tolerance: 5% n/s / 5% e/w (Higher values should be validated)
Tracking Range: +/-55°
Standard Configuration: 1 Portrait
Preventative Maintenance Required:
Annual visual inspection and torque verification
Tracker Power Consumption: Self- powered
Certifications: UL 2703, UL 3703, IEC 62817
Key Features:
• Robust design; minimum number of failure points with only 4 actuators per MW. Rows are mechanically linked with simple pin articulated connections;
• Easy installation; no need of specific tools or on-site pre-assembly (no hidden cost on tool investment);
• Number of rows and length can be adjusted to specific site layout and string requirements;
• Self-powered or Parasitic power supply with back-up battery and wireless communication eliminates the need of AC and communications wiring;
• Maintenance free; gear is lubricated and sealed for life.
www.stinorland.com
GameChange Solar
Type of Tracker: Single-axis
Drive System: Linear actuator
Modules per Row: TBD on string size
Module Mount: Bolts, nuts, star washer, clamp, or SpeedClamp (no module mounting hardware required)
Slope Tolerance: n/s slopes of 7%, e/w slopes of 15%
Tracking Range: +/- 45°, +/-52°, +/-60° Standard Configuration: 1 up in portrait Certifications: UL 2703, UL3703 Tested www.gamechangesolar.com
Lowest Installed and O&M Costs for the Harshest Conditions
Ideematec
Type of Tracker: Single-axis, horizontal
tracking system
Drive System: Single row electrical drive unit (AC and DC)
Tracker Length): 500' (150m)
Tracker Height (top of posts): 13.2' (4m)
Pile Count: 16 modules/foundation
Modules per Row: 2 modules in portrait or 4 modules in landscape
Module Mount: Rivets
Slope Tolerance: 36% N/W/S/E
Krinner Solar LLC
Type of Tracker: Krinner Tracking System
Drive System: Linked system with screw jack, single drive also available
Tracker Length: Up to 325' (99m); standard linked 204' (62m); standard single drive 270' (82.5m)
Tracker Height: Center pivot axis 4.26' (1.3m) Pile Count: 400 to 500 piles per MW,
depending on wind and soil conditions
Modules per Row: Up to 96 (for 1500V strings); standard linked 60 modules; standard single drive 80 modules
Module Mount: Standard one row vertical (in portrait); 2 or 3 in landscape possible
Slope Tolerance: Rigid pivot axis n/s 6° / 10%; e/w 10° / 17%; pivot axis with universal joint (hinged system) n/s 15° / 26% per joint
Tracking Range: Up to 58°
Standard Configuration: 2 modules in portrait on 28-32 rows per table; 5 tables per tracker
Preventative Maintenance Required:
Recommended but not required
Tracker Power Consumption: 1800kwh / MWp per year
Certifications: UL, CE, TUV www.ideematec.com
Tracking Range: -50° to + 50° for linked system (central drive); -60° to + 60° for single drive
Standard Configuration: Central drive: 60 to 84 modules (72 cells) in portrait; single drive: 80 to 96 modules (72 cells) in portrait
Preventative Maintenance Required:
Central drive: no maintenance, only the
screw jack once per year; single drive: no maintenance, only the oil-level in the slew gear must be checked (through oil level windows)
Tracker Power Consumption: Central drive: 300kWh/MW and year (average); single drive: standard self-powered > 0 consumption
Certifications: Designed according to standards DIN; EN ISO; UL, TÜV certifications
www.krinner-solar.com
PHLEGON® SINGLE AXIS TRACKER
April 30-May 2 November 13-14
June September 20-21 24-27
October 19-20
December 13-14
All year round
Visit us in
GP JOULE is a global renewable energy company with an extensive track record in com- mercial and utility-scale ground mount PV. Our proprietary PHLEGON® single axis tracker, designed for northern climates and challenging sites, comes with a complete offering of engineering, installation and commissioning services. Learn more at www.gp-joule.com.
Ad-GPJOUMLEA-4R87C5xH35•0A0-P21R02IL202180.i1n8dd /1// www.nacleanenergy.com 21/02/2018 15:18 40
Minneapolis
Calgary
Anaheim
Chicago
New York
Toronto