Page 34 - North American Clean Energy July/August 2020 Issue
P. 34
solar spotlight: performance monitoring
SEE AD ON PAGE 33 SEE AD ON PAGE 32
Solmetric
Product: PV Analyzer I-V Curve Tracer Voltage: 1500V
Current: 30A
Power: 45kW
Warranty: 1-year warranty Certifications: TUV
Key Features:
• Measure I-V curves up to 1500V at 30A;
• Wireless interface to irradiance sensor with 300ft range;
• Highest measurement throughput;
• Large, easy-to-use user interface.
www.solmetric.com
OTT HydroMet
Product: DustIQ Soiling Monitoring System Voltage: 24Vdc
Current: 300mA maximum
Frequency: 0Hz
Logging Values: Soiling Ratio (%), transmission loss [%], Back of module temperature [°K]
Measurement Range: Soiling ratio 100% to 50%
Output: Modbus RTU over RS-485
Sensitivity: 0.1% soiling ratio Warranty: 2-year warranty Key Features:
• Know exactly when and where to clean;
• Optimize yield;
• Maintenance free;
• Integrated into leading plant management software.
www.otthydromet.com
WATTNODE® ME WIDE-RANGE MODBUS ENERGY METER
NOW AVAILABLE with up to 84 SINGLE CIRCUITS
(or 28 three-phase circuits)
One Model for all Utility Services
• Supports 100 to 600 Vac
Corrects Wiring Errors Remotely
• Reconfigure the CTs Polarity
ANSI C12.20 Class 0.5 Accuracy
• Uses Safe Low-Voltage (0.333Vac) CTs
Modbus RTU, RS-485 Communication Adjustable Baud Rates to 115K
1-888-WattNode (928-8663) • ctlsys.com
Apogee Instruments
Product: Silicon-cell Pyranometer SP-110
Voltage: 0 - 400mV
Warranty: 4-year warranty against defects in materials and workmanship
www.apogeeinstruments.com
34
JULY•AUGUST 2020 ///
www.nacleanenergy.com
Accuenergy (Canada) Inc. Product: Acuvim II Series
Solar Data Systems
Product: Solar-Log 2050 Commercial Revenue Grade Meter
Voltage: 600V or 600/347V, 480V or 480/277V, 208V or 208/120V, 240V or 240/120V, Single (split) phase, Three Phase
Current: 200mA via mA CTs Power: 120-277Vac Frequency: 50Hz or 60Hz
Logging Values: Voltage [V] (A, B, C, Avg, AB, AC, BC, Avg); Current [A] (A, B, C, Avg); Active Power [W] (A, B, C, Total) – Bi- directional; Apparent Power [VA] (A, B, C, Total) Reactive Power [VAR] (A, B, C, Total) — Bi-directional; Power Factor (A, B, C, System) — Bi-directional; Active Quadrant (A, B, C, System); Voltage Phase Angle [°] (AB, AC, BC); Frequency [Hz]; Import/ Export/Net Real Energy [Wh] (A, B, C, Total); Import/Export/Net Apparent Energy [VAh] (A, B, C, Total); Q1/Q2/Q3/Q4 Reactive Energy [VARh] (A, B, C, Total); Total Demand Power (Sliding Window) [W]
Measurement Range: 450VAC L-N, 780V L-L Output: RS-485 + Pulse (Modbus/RTU) Sensitivity: 0.2% max
Warranty: 1-year warranty
Certifications: ANSI C12.20 Class 0.2 Accuracy Certified, Indoor/Outdoor IP-67
www.solar-log-america.com
TER ENCLOSURES
Voltage: Voltage V1, V2, V3, Vlnavg, V12, V23, V31, Vllavg
Current: Current I1, I2, I3, In, Iavg
Power: P1, P2, P3, Psum
Logging Values: F, V1/2/3/lnavg, V12/23/13/lavg, I1/2/3/n/avg, P1/2/3/sum, Q1/2/3/sum, S1/2/3/sum, PF1/2/3, PF, U_unbl, I_unbl, Load Type, Ep_imp, Ep_ exp, Ep_total, Ep_net, Eq_imp, Eq_exp, Eq_total, Eq_net, Es, Epa_imp, Epa_exp, Epb_imp,Epb_ exp, Epc_imp, Epc_exp, Eqa_imp, Eqa_exp, Eqb_imp, Eqb_exp, Eqc_imp, Eqc_exp, Esa, Esb, Esc, THD_V1/2/3/avg, THD_I1/2/3/avg, Harmonics 2nd to 63rd, Crest Factor, THFF, K Factor, Sequence and Phase Angles, DI Counter, AI, AO, Dmd P/Q/S, Dmd I1/2/3
Warranty: 5-year warranty
Certifications: Revenue grade ANSI C12.20 class
0.2 & IEC 62053-22 class 0.2s
www.accuenergy.com/meter
New Product!